Drive Commander · Rockwell Automation PowerFlex 525
Rockwell Automation PowerFlex 525 fault codes, decoded for the technician in front of the drive.
Search a fault code. Get what it means and the exact parameters to check — every answer cited to the PowerFlex 525 manual. No PDF hunting, no generic AI guesses.
Grounded · PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E) · manual-cited
47 PowerFlex 525 faults in this pack · 5 with cited troubleshooting detail
Each code below is decoded from the PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E) — the full manual covers more; we only publish what we can cite. Click a code for the cited meaning and the parameters to check.
F007
Motor Overload
cited detail
F081
DSI Comm Loss
cited detail
F082
Opt Comm Loss
cited detail
F083
EN Comm Loss
cited detail
F101
External Storage
cited detail
F002
Auxiliary Input
in pack
F003
Power Loss
in pack
F004
UnderVoltage
in pack
F005
OverVoltage
in pack
F006
Motor Stalled
in pack
F008
Heatsink OvrTmp
in pack
F009
CC OvrTmp
in pack
F012
HW OverCurrent
in pack
F013
Ground Fault
in pack
F015
Load Loss
in pack
F021
Output Ph Loss
in pack
F029
Analog In Loss
in pack
F033
Auto Rstrt Tries
in pack
F038
Phase U to Gnd
in pack
F039
Phase V to Gnd
in pack
F040
Phase W to Gnd
in pack
F041
Phase UV Short
in pack
F042
Phase UW Short
in pack
F043
Phase VW Short
in pack
F048
Params Defaulted
in pack
F059
Safety Open
in pack
F063
SW OverCurrent
in pack
F064
Drive Overload
in pack
F070
Power Unit
in pack
F071
DSI Net Loss
in pack
F072
Opt Net Loss
in pack
F073
EN Net Loss
in pack
F080
Autotune Failure
in pack
F091
Encoder Loss
in pack
F094
Function Loss
in pack
F100
Parameter Chksum
in pack
F105
C Connect Err
in pack
F106
Incompat C-P
in pack
F107
Replaced C-P
in pack
F109
Mismatch C-P
in pack
F110
Keypad Membrane
in pack
F111
Safety Hardware
in pack
F114
uC Failure
in pack
F122
I/O Board Fail
in pack
F125
Flash Update Req
in pack
F126
NonRecoverablErr
in pack
F127
DSIFlashUpdatReq
in pack
Parameter reference (45)
Cited PowerFlex 525 parameters — click one for its manual reference.
C121Comm Write ModeC122Cmd Stat SelectC123RS485 Data RateC124RS485 Node AddrC125Comm Loss ActionC126Comm Loss TimeC127RS485 FormatC128EN Addr SelC129EN IP Addr Cfg 1C130EN IP Addr Cfg 2C131EN IP Addr Cfg 3C132EN IP Addr Cfg 4P030LanguageP031Motor NP VoltsP032Motor NP HertzP033Motor OL CurrentP034Motor NP FLAP035Motor NP PolesP036Motor NP RPMP037Motor NP PowerP039Torque Perf ModeP040AutotuneP041Accel Time 1P042Decel Time 1P043Minimum FreqP044Maximum FreqP045Stop ModeP052Average kWh CostP053Reset To Defaultst091Anlg In 0-10V Lot092Anlg In 0-10V Hit09310V Bipolar Enblt094Anlg In V Losst095Anlg In4-20mA Lot096Anlg In4-20mA Hit097Anlg In mA Losst098Anlg Loss Delayt099Analog In Filtert100Sleep-Wake Selt101Sleep Levelt102Sleep Timet103Wake Levelt104Wake Timet105Safety Open Ent106SafetyFlt RstCfg
Go deeper with Drive Commander Pro
Drive Commander Pro
The full cited pack
- Every parameter reference with value/setting tables
- Wiring, terminal, and I/O checks
- Control-source setup & reset / recovery workflow
- Ask-MIRA follow-up questions on this exact drive
- Saved troubleshooting history & pack updates
Cancel anytime · 30-day money-back guarantee