Rockwell Automation PowerFlex 525 · Parameter t099
t099 — Analog In Filter
Sets the level of additional filtering of the analog input signals. The higher number increases filtering and decreases bandwidth. Each setting doubles the applied filtering (1 = 2x filter, 2= 4x filter, and so on). No additional filtering is applied when set to “0”. Values Min/Max: 0 /14
Grounded · PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E) · manual-cited
Cited reference
t099
Analog In Filter
Sets the level of additional filtering of the analog input signals. The higher number increases filtering and decreases bandwidth. Each setting doubles the applied filtering (1 = 2x filter, 2= 4x filter, and so on). No additional filtering is applied when set to “0”. Values Min/Max: 0 /14
PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E), p.100
“t099 [Analog In Filter] Related Parameters: t091, t092, t095, t096”