Rockwell Automation PowerFlex 525 · Parameter t096
t096 — Anlg In4-20mA Hi
Stop drive before changing this parameter. Sets the percentage (based on 4…20 mA) of input current applied to the 4…20 mA analog input that is used to represent P044 [Maximum Freq]. Analog inversion can be accomplished by setting this value smaller than t095 [Anlg In4-20mA Lo].
Grounded · PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E) · manual-cited
Cited reference
t096
Anlg In4-20mA Hi
Stop drive before changing this parameter. Sets the percentage (based on 4…20 mA) of input current applied to the 4…20 mA analog input that is used to represent P044 [Maximum Freq]. Analog inversion can be accomplished by setting this value smaller than t095 [Anlg In4-20mA Lo].
PowerFlex 525 Adjustable Frequency AC Drive User Manual (520-UM001O-EN-E), p.100
“t096 [Anlg In4-20mA Hi] Related Parameters: P044, t095”